Media 000010129: Cranium [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000010129
Media type
CTImageSeries
File format(s)
image/tiff
File size
2.62 GB
Object element or part
cranium
Side
NotApplicable
Orientation
--
Short description
zipped tiff stack of microCT slices
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack of microCT slices Migrated MorphoSource 1 Media Group Title: zipped tiff stack of microCT slices
Creator
--
Date created
--
Date uploaded
March 10, 2016
Image width
1432
Image height
1217
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.062021
Y pixel spacing
0.062021
Z pixel spacing
0.062021
Pixel spacing units
Mm
Number of images in set
1,846
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Ken Glander
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
du:ea:LP21
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Emily Laub
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
135
Power
0.0072
Amperage
72
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000010129: Cranium [CTImageSeries] [Etc]
(this media).
Processing Details
Creator
Emily Laub
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource