Media 000012622: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000012622
Media type
CTImageSeries
File format(s)
image/jpeg
File size
509 MB
Object element or part
--
Side
--
Orientation
--
Short description
The Slice data
Full description
Migrated MorphoSource 1 Media File Title: The Slice data Migrated MorphoSource 1 Media Group Title: JPG stack
Creator
--
Date created
--
Date uploaded
May 17, 2016
Image width
1076
Image height
512
Color space
--
Color depth
8/8/8
Compression
--
X pixel spacing
0.024800
Y pixel spacing
0.024800
Z pixel spacing
0.024800
Pixel spacing units
Mm
Number of images in set
3,837

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1172, Bruker MicroCT (Bruker MicroCT)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
Adam P. Summers and Kevin W. Conway
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701665
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Kevin W. Conway and Adam P. Summers provided access to these dataoriginally appearing in the collection of which was funded by Karel F. Liem Bioimaging Facility. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nhmuk:2001.1.21.58-71 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1172
Device facility
Bruker MicroCT (Bruker MicroCT)
Creator
Kevin W. Conway and Adam P. Summers
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
60
Power
--
Amperage
110
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000012622: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Kevin W. Conway and Adam P. Summers
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000012622: Element Unspecified [CTImageSeries] [Etc] (this media)