Media 000042791: 16 Bit Tiff Stack
Restricted Download
Type
CT Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Media 000042791: 16 Bit Tiff Stack
Restricted Download
Type
CT Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS
Media ID
000042791
Media type
CT Image Series
Object element or part
16 bit tiff stack
Object represented
Object taxonomy
Atelopus zeteki
Object organization
Side
--
Orientation
--
Short description
Tiff-stack
Full description
Migrated MorphoSource 1 Media File Title: Tiff-stack Migrated MorphoSource 1 Media Group Title: CT scan of mcz-herp-a-136548, Atelopus zeteki
Creator
--
Date created
--
Date uploaded
March 02, 2018
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
2.25 GB
Image width
599
Image height
1303
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.024657
Y pixel spacing
0.024657
Z pixel spacing
0.024657
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,868
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert Thematic Collections Network (TCN), NSF DBI-1701714, 1702263
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MCZ:Herp:A-136548
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
2200
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000042791: 16 Bit Tiff Stack [CTImageSeries] [Etc] (this media).
Processing Details
Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None