Media 000057519: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000057519
Media type
CTImageSeries
File format(s)
image/tiff
File size
8,648,738,357 bytes
Object element or part
--
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Micro-CT volume and derivative mesh files
Creator
--
Date created
--
Date uploaded
September 06, 2018
Image width
1474
Image height
1662
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.01709
Y pixel spacing
0.01709
Z pixel spacing
0.01709
Pixel spacing units
Mm
Number of images in set
1,999

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, Imaging and Analysis Centre (The Natural History Museum)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
Serjoscha W. Evers (PLY files); Natural History Museum London (CT data)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Serjoscha W. Evers provided access to these dataoriginally appearing in … , the collection of which was funded by a NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nhmuk:pal:PV OR 35197 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225
Device facility
Imaging and Analysis Centre (The Natural History Museum)
Creator
Serjoscha Evers
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
4
Projections
3142
Voltage
215
Power
--
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000057519: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Serjoscha Evers
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000057519: Element Unspecified [CTImageSeries] [Etc] (this media)