Media 000082166: Cranium [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000082166
Media type
Mesh
Object element or part
cranium
Side
NotApplicable
Orientation
--
Short description
Mesh file (STL)
Full description
Migrated MorphoSource 1 Media File Title: Mesh file (STL) Migrated MorphoSource 1 Media Group Title: CT scan of UF2760, Amphiuma means
Creator
--
Date created
--
Date uploaded
June 27, 2019

FILE OBJECT DETAILS

File format(s)
application/stl
File size
189 MB
Points
507,765
Polygons
1,019,165
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
42.184, 25.920, 14.015
Centroid coordinates
-0.639, -0.129, -3.613
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
Florida Museum of Natural History, University of Florida
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert Thematic Collections Network (TCN), NSF DBI-1701714
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:2760 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2200
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000036807: 16bit Tiffs [CTImageSeries] [Etc] .

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000036807: 16bit Tiffs [CTImageSeries] [Etc] was processed to create derived Media 000082166: Cranium [Mesh] [Etc] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000082166: Cranium [Mesh] [Etc] (this media)