Media 000113920: Entire Specimen [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000113920
Media type
CTImageSeries
Object element or part
entire specimen
Side
NotApplicable
Orientation
--
Short description
DICOM image stack xz-plane
Full description
Migrated MorphoSource 1 Media File Title: DICOM image stack xz-plane Migrated MorphoSource 1 Media Group Title: DICOM image stack xz-plane Migrated MorphoSource 1 Media File Description: merged from 3 stacked scans
Creator
--
Date created
--
Date uploaded
March 31, 2020

FILE OBJECT DETAILS

File format(s)
application/dicom
File size
13.4 GB
Image width
1970
Image height
2392
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.034891
Y pixel spacing
0.034891
Z pixel spacing
0.034891
Pixel spacing units
Mm
Number of images in set
1,672

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
The Hunterian, University of Glasgow
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object glahm:A23133 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Morgan H Chase
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1800 per scan
Voltage
190
Power
--
Amperage
180
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000113920: Entire Specimen [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Morgan H Chase
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000113920: Entire Specimen [CTImageSeries] [Etc] (this media)