Media 000115578: Skull [Mesh] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000115578
Media type
Mesh
File format(s)
application/stl
File size
178 MB
Object element or part
Skull
Side
--
Orientation
--
Short description
3D Mesh of Skull
Full description
Migrated MorphoSource 1 Media File Title: 3D Mesh of Skull Migrated MorphoSource 1 Media Group Title: whole body scan Migrated MorphoSource 1 Media File Description: Created by Anne-Claire Fabre
Creator
--
Date created
--
Date uploaded
May 04, 2020
Points
355,615
Polygons
710,563
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3.520, 3.621, 5.123
Centroid coordinates
-0.133, -0.171, -4.403
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
uf:herp:62921
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.500093
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1050
Voltage
70
Power
0.008400000000000001
Amperage
120
Surrounding material
1
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000049703: Element Unspecified [CTImageSeries] [Etc]
.
Processing Details
Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000049703: Element Unspecified [CTImageSeries] [Etc]
was processed
to create
derived
Media 000115578: Skull [Mesh] [Etc]
(this media).
Processing Details
Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource

Media 000115578: Skull [Mesh] [Etc] (this media)