Media 000024023: Ct Scan Of Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000024023
Media type
Volumetric Image Series
Object element or part
CT Scan of body
Object represented
Object taxonomy
Homalopteroides nebulosus
Side
--
Orientation
--
Short description
UF235748_Hnebulosus
Full description
Migrated MorphoSource 1 Media File Title: UF235748_Hnebulosus Migrated MorphoSource 1 Media Group Title: CT scan of UF-I-235748
Creator
--
Date created
--
Date uploaded
March 07, 2017

FILE OBJECT DETAILS Field Definitions

File name
UF235748_Hnebulosus.zip
File format(s)
ZIP archive, TIFF
File size
1.89 GB
Image width
600
Image height
2024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.020001
Y pixel spacing
0.020001
Z pixel spacing
0.020001
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,703

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF ADBC 47033
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Fish:235748 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall and Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
200.098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
800
Voltage
80
Power
0.012
Amperage
150
Surrounding material
off
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000024023: Ct Scan Of Body [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Zachary Randall and Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000024023: Ct Scan Of Body [CTImageSeries] [Etc] (this media)