Media 000000831: Ramus Fragment 6 [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000000831
Media type
Mesh
File format(s)
application/ply
File size
10.4 MB
Object element or part
Ramus fragment 6
Side
Unknown
Orientation
--
Short description
Smooth Surface file
Full description
Migrated MorphoSource 1 Media File Title: Smooth Surface file Migrated MorphoSource 1 Media Group Title: Raw Surface file Migrated MorphoSource 1 Media File Description: Smooth surface. Migrated MorphoSource 1 Media Group Description: Raw surface.
Creator
--
Date created
--
Date uploaded
September 05, 2013
Points
151,956
Polygons
299,726
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
11.647, 10.664, 14.655
Centroid coordinates
22.791, 22.941, 13.443
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
University of California Regents; University of California Museum of Paleontology
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ucmp:v:38989 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
3142
Voltage
160
Power
--
Amperage
165
Surrounding material
none
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000000831: Ramus Fragment 6 [Mesh] [Etc] (this media).

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000000831: Ramus Fragment 6 [Mesh] [Etc] (this media)