Media 000001796: Ramus Frags 1 3 And Condyle [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000001796
Media type
CTImageSeries
Object element or part
ramus frags 1-3 and condyle
Side
Unknown
Orientation
--
Short description
Zipped microCT image stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped microCT image stack Migrated MorphoSource 1 Media Group Title: Zipped microCT image stack Migrated MorphoSource 1 Media File Description: zipped image stack. TIFF format. Migrated MorphoSource 1 Media Group Description: zipped image stack. TIFF format.
Creator
--
Date created
--
Date uploaded
November 05, 2013

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
1.94 GB
Image width
1973
Image height
1849
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.020858
Y pixel spacing
0.020858
Z pixel spacing
0.020858
Pixel spacing units
Mm
Number of images in set
1,588

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
University of California Museum of Paleontology; University of California Regents
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ucmp:v:38989 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
3142
Voltage
160
Power
--
Amperage
165
Surrounding material
none
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000001796: Ramus Frags 1 3 And Condyle [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000001796: Ramus Frags 1 3 And Condyle [CTImageSeries] [Etc] (this media)