Media 000002905: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000002905
Media type
CTImageSeries
Object element or part
--
Side
Unknown
Orientation
--
Short description
MCZ 21153 skull
Full description
Migrated MorphoSource 1 Media File Title: MCZ 21153 skull Migrated MorphoSource 1 Media Group Title: MCZ 21153 skull
Creator
--
Date created
--
Date uploaded
September 02, 2014

FILE OBJECT DETAILS

File format(s)
application/dicom
File size
3.21 GB
Image width
1237
Image height
1672
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.076020
Y pixel spacing
0.076020
Z pixel spacing
0.076020
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,108

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, Center for Nanoscale Systems (Harvard University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Lynn Lucas and Lynn Copes provided access to these data NSF DDIG #0925793 and the Wenner Gren Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mcz:mamm:21153 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
1050
Voltage
70
Power
0.0077
Amperage
110
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000002905: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000002905: Element Unspecified [CTImageSeries] [Etc] (this media)