Media 000005388: Femur
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000005388
Media type
Volumetric Image Series
Object element or part
femur
Object represented
Object taxonomy
Tomistoma schlegelii
Side
Right
Orientation
--
Short description
Tschl CT scan data
Full description
Migrated MorphoSource 1 Media File Title: Tschl CT scan data Migrated MorphoSource 1 Media Group Title: ZIP file of CT scan data Migrated MorphoSource 1 Media Group Description: Midshaft ~slice 486
Creator
--
Date created
--
Date uploaded
April 24, 2015

FILE OBJECT DETAILS Field Definitions

File name
Tom-schlegeli-TMM-VPL-M-6820-fem.zip
File format(s)
ZIP archive, DICOM
File size
32.9 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
96.000000
Y pixel spacing
96.000000
Z pixel spacing
0.625000
Pixel spacing units
Mm
Slice thickness
0.625000
Number of images in set
195

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
University of Texas at Austin
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR-1250123
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:m:6820 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Sarah Werning
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
200000
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000005388: Femur [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Sarah Werning
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000005388: Femur [CTImageSeries] [Etc] (this media)