Media 000008862: Lower M2 [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

2 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000008862
Media type
Mesh
File format(s)
application/ply
File size
190,917 bytes
Object element or part
Lower M2
Side
Right
Orientation
--
Short description
Lower M2 Processed and Faired
Full description
Migrated MorphoSource 1 Media File Title: Lower M2 Processed and Faired Migrated MorphoSource 1 Media Group Title: Lower M2 Ply Files (analyzed in molaR paper) Migrated MorphoSource 1 Media Group Description: Modified from previously segmented lower M2 represented by morphosource media group M752-632
Creator
--
Date created
--
Date uploaded
February 02, 2016
Points
5,063
Polygons
9,997
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.376, 8.194, 4.955
Centroid coordinates
4.326, -5.3, 2.125
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Open Download
Download reviewer
--
IP holder(s) (Name, Type)
D.M. Boyer
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Paul E. Morse provided access to these datawhich are derived from M752-632 provided by D.M. Boyer and first appeared in Pampush et al. (2016). Raw data collection was funded by the following grants: BCS-0129601, EAR-0308902, BCS-0622544, and DDIG 40761-0001. The files were downloaded from www.MorphoSource.org, Duke University.
Additial usage agreement
None
Media preview mode
--

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:mammals:281658 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Paul E. Morse; James D. Pampush
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000015496: Lower M2 [Mesh] [Etc] .

Processing Details

Creator
James D. Pampush, Paul E. Morse
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000015496: Lower M2 [Mesh] [Etc] was processed to create derived Media 000008862: Lower M2 [Mesh] [Etc] (this media).

Processing Details

Creator
Paul E. Morse, James D. Pampush
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000008862: Lower M2 [Mesh] [Etc] (this media)