Media 000010176: Lower M1 [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000010176
Media type
Mesh
File format(s)
application/ply
File size
322,630 bytes
Object element or part
Lower M1
Side
Left
Orientation
--
Short description
Lower M1 Raw
Full description
Migrated MorphoSource 1 Media File Title: Lower M1 Raw Migrated MorphoSource 1 Media Group Title: Lower M1 Ply Files (example tooth for molaR paper) Migrated MorphoSource 1 Media Group Description: molaR ex_tooth2
Creator
--
Date created
--
Date uploaded
March 11, 2016
Points
5,135
Polygons
9,997
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.914, 8.362, 3.168
Centroid coordinates
2.956, 22.835, 72.579
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
K.L. Allen
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Paul E. Morse provided access to these datawhich are derived from M4147-7568 provided by K.L. Allen and first appeared in Pampush et al. (2016). Raw data collection was funded by NSF DDIG and the Leakey Foundation to K.L. Allen. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:LP07 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Paul E. Morse; James D. Pampush
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
--
Projections
2800
Voltage
205
Power
--
Amperage
175
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000010176: Lower M1 [Mesh] [Etc] (this media).

Processing Details

Creator
Paul E. Morse, James D. Pampush
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000010176: Lower M1 [Mesh] [Etc] (this media)