Media 000012492: Cranium, Mandible [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000012492
Media type
Mesh
Object element or part
Cranium, mandible
Side
NotApplicable
Orientation
--
Short description
PLY
Full description
Migrated MorphoSource 1 Media File Title: PLY Migrated MorphoSource 1 Media Group Title: CT Scan
Creator
--
Date created
--
Date uploaded
May 12, 2016

FILE OBJECT DETAILS

File format(s)
application/ply
File size
46.5 MB
Points
1,251,432
Polygons
2,593,759
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
108.809, 104.635, 145.343
Centroid coordinates
55.009, 46.192, 70.371
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Eric Delson and the AMNH Department of Mammalogy provided access to these data , the collection of which was funded by AMNH and NYCEP. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:mammals:m-35640 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
1235
Voltage
--
Power
--
Amperage
--
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000012489: Cranium, Mandible [CTImageSeries] [Etc] .

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000012489: Cranium, Mandible [CTImageSeries] [Etc] was processed to create derived Media 000012492: Cranium, Mandible [Mesh] [Etc] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000012492: Cranium, Mandible [Mesh] [Etc] (this media)