Media 000020495: Radius [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

2 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000020495
Media type
CTImageSeries
File format(s)
image/tiff
File size
530,932,873 bytes
Object element or part
Radius
Side
Left
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack, Raw Surface Mesh, Smooth Surface Mesh Migrated MorphoSource 1 Media File Description: reversed chirality Migrated MorphoSource 1 Media Group Description: reversed chirality
Creator
--
Date created
--
Date uploaded
December 09, 2016
Image width
1024
Image height
550
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.0502688
Y pixel spacing
0.0502688
Z pixel spacing
0.0502688
Pixel spacing units
Mm
Number of images in set
3,166

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Duke University, Evolutionary Anthropology, Durham, NC, USA
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1552848 to D Boyer, and Duke ASC FRC to A. Gosselin-Ildari and D. Schmitt
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in , the collection of which was funded by NSF BCS 1552848 to D Boyer, and Duke ASC FRC to A. Gosselin-Ildari and D. Schmitt. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:baa:90 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Ana Galvez
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
1
Projections
2000
Voltage
125
Power
--
Amperage
116
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000020495: Radius [CTImageSeries] [CT] (this media).

Processing Details

Creator
Doug Boyer, Ana Galvez
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000020495: Radius [CTImageSeries] [CT] (this media)