Media 000025067: Ct Scan Of Skeleton And Skull [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000025067
Media type
CTImageSeries
Object element or part
CT scan of skeleton and skull
Side
--
Orientation
--
Short description
Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Tiff Stack Migrated MorphoSource 1 Media Group Title: CT scan of Gastrophryne carolinensis
Creator
--
Date created
--
Date uploaded
March 29, 2017

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
2.26 GB
Image width
1174
Image height
590
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.016418
Y pixel spacing
0.016418
Z pixel spacing
0.016418
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,021

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
Florida Museum of Natural History, University of Florida
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
University of Florida
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:110645 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1400
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000025067: Ct Scan Of Skeleton And Skull [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000025067: Ct Scan Of Skeleton And Skull [CTImageSeries] [Etc] (this media)