Media 000031957: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

Interactive/Embeddable Media Preview is currently unavailable. Please check back later.

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000031957
Media type
CTImageSeries
File format(s)
image/jpeg
File size
3,725,871 bytes
Object element or part
--
Side
--
Orientation
--
Short description
Troglichthys rosae - images/ slice data/ log data
Full description
Migrated MorphoSource 1 Media File Title: Troglichthys rosae - images/ slice data/ log data Migrated MorphoSource 1 Media Group Title: Troglichthys rosae - images/ slice data/ log data
Creator
--
Date created
--
Date uploaded
August 29, 2017
Image width
696
Image height
172
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.0628
Y pixel spacing
0.0628
Z pixel spacing
0.0628
Pixel spacing units
Mm
Number of images in set
1

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701665
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tu:fish:22675 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
--
Projections
--
Voltage
60
Power
--
Amperage
110
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000031957: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000031957: Element Unspecified [CTImageSeries] [Etc] (this media)