Media 000038153: Wet Specimen Full Body [Image] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000038153
Media type
Image
Object element or part
wet specimen full body
Side
NotApplicable
Orientation
--
Short description
preview image of dicom stack
Full description
Migrated MorphoSource 1 Media File Title: preview image of dicom stack Migrated MorphoSource 1 Media Group Title: medical CT scan and derivatives Migrated MorphoSource 1 Media File Description: 1,577 slices
Creator
--
Date created
--
Date uploaded
December 04, 2017

FILE OBJECT DETAILS

File format(s)
image/jpeg
File size
243 KB
Image width
1824
Image height
1672
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.876580
Y pixel spacing
0.877645
Z pixel spacing
0.400000
Pixel spacing units
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Somatom Perspective 64 Computed, NC State Veterinary Hospital, Diagnostic Imaging Department (North Carolina State University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1552848 (to DM Boyer) and NSF DBI 1701714 (to D Blackburn, E. Stanley, JI Boch and DM Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data NSF BCS 1552848 and NSF DBI 1701714. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:mammals:m-202870 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Somatom Perspective 64 Computed
Device facility
NC State Veterinary Hospital, Diagnostic Imaging Department (North Carolina State University)
Creator
James Robey
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000038741: Wet Specimen, Full Body [CTImageSeries] [Etc] .

Processing Details

Creator
James Robey
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000038741: Wet Specimen, Full Body [CTImageSeries] [Etc] was processed to create derived Media 000038153: Wet Specimen Full Body [Image] [Etc] (this media).

Processing Details

Creator
James Robey
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000038153: Wet Specimen Full Body [Image] [Etc] (this media)