Media 000039443: Partial Tooth [Mesh] [CT]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000039443
Media type
Mesh
File format(s)
application/ply
File size
35 MB
Object element or part
partial tooth
Side
--
Orientation
--
Short description
PU/VPL/RS87
Full description
Additional Notes: Found at Sunetar 1, Ramnagar, India. GPS Coordinates given in Gilbert et al. 2014.
Creator
--
Date created
--
Date uploaded
January 14, 2018
Points
487,885
Polygons
975,758
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
13.812, 12.649, 10.795
Centroid coordinates
23.113, 28.564, 36.321
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Molecular Imaging Center (University of Southern California)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Biren Patel
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
National Science Foundation (BCS-1945618 to Biren A. Patel; BCS-1945736 to Christopher C. Gilbert)
Publisher
Department of Geology Vertebrate Paleontology Laboratory, Panjab University
Cite as
These data are part of the project "Siwalik Fossils from Ramnagar (Jammu & Kashmir), India" hosted on www.MorphoSource.org (Duke University); the project's curation is funded by the National Science Foundation (BCS-1945618 to Biren A. Patel and BCS-1945736 to Christopher C. Gilbert).
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object pu:vpl:RS87 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Molecular Imaging Center (University of Southern California)
Creator
Biren Patel
Date
2021-04-09
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1440
Voltage
120
Power
--
Amperage
130
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000039529: Partial Tooth [CTImageSeries] [CT] .

Processing Details

Creator
Biren Patel
Date processed
2021-04-09
Software
--
Description
Inquire with creator
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000039529: Partial Tooth [CTImageSeries] [CT] was processed to create derived Media 000039443: Partial Tooth [Mesh] [CT] (this media).

Processing Details

Creator
Biren Patel
Date processed
2021-04-09
Software
--
Description
The 3D surface uploaded for this specimen was produced with the LabelField functions in AMIRA v.6.4, and is best regarded as minimally processed for smoothing and hole filling (unless otherwise noted).
Description attachment
None

Media produced by this event on MorphoSource


Media 000039443: Partial Tooth [Mesh] [CT] (this media)