Media 000042728: 3 D Mesh (Ply)
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000042728
Media type
Mesh
Object element or part
3D Mesh (PLY)
Object represented
Object taxonomy
Lepidochelys olivacea
Side
Left
Orientation
--
Short description
Left Prearticular
Full description
Migrated MorphoSource 1 Media File Title: Left Prearticular Migrated MorphoSource 1 Media Group Title: microCT volume files and mesh files
Creator
--
Date created
--
Date uploaded
March 02, 2018

FILE OBJECT DETAILS Field Definitions

File name
Lepidochelys_olivacea_L-Praearticular.ply
File format(s)
PLY
File size
3.33 MB
Points
79692
Polygons
158342
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9364.563, 40453.859, 20123.529
Centroid coordinates
83758.806, 155733.536, 15300.666
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Serjoscha W. Evers (PLY files); Staatliches Museum für Naturkunde Stuttgart (CT data)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Serjoscha W. Evers provided access to these dataoriginally appearing in Evers & Benson (2018) , the collection of which was funded by a NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object smns:11070 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
354 msec
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
170
Power
--
Amperage
396
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000042678: Dicom Stack [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000042678: Dicom Stack [CTImageSeries] [Etc] was processed to create derived Media 000042728: 3 D Mesh (Ply) [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000042728: 3 D Mesh (Ply) [Mesh] [CT] (this media)