Media 000049266: Distal Phalanx, Manual Digit 2 [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000049266
Media type
CTImageSeries
Object element or part
distal phalanx, manual digit 2
Side
Right
Orientation
--
Short description
zipped dcm stack
Full description
Migrated MorphoSource 1 Media File Title: zipped dcm stack Migrated MorphoSource 1 Media Group Title: micro CT volume and derivative mesh Migrated MorphoSource 1 Media File Description: reversed chirality Migrated MorphoSource 1 Media Group Description: reversed chirality
Creator
--
Date created
--
Date uploaded
May 30, 2018
FILE OBJECT DETAILS
File format(s)
application/dicom
File size
3.2 MB
Image width
151
Image height
198
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.037380
Y pixel spacing
0.037380
Z pixel spacing
0.037380
Pixel spacing units
Mm
Number of images in set
90
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Smithsonian, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in , the collection of which was funded by NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
usnm:mammals:83652
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Justin Gladman, Mackenzie Aguilar, Jong Gwan Lee
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1600
Voltage
150
Power
0.00825
Amperage
165
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000049266: Distal Phalanx, Manual Digit 2 [CTImageSeries] [Etc]
(this media).
Processing Details
Creator
Justin Gladman, Mackenzie Aguilar, Jong Gwan Lee
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000049266: Distal Phalanx, Manual Digit 2 [CTImageSeries] [Etc] (this media)