Media 000063189: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000063189
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Micrurus ancoralis
Side
NotApplicable
Orientation
--
Short description
CT of pathogenic Vertebrae - R-55945
Full description
Migrated MorphoSource 1 Media File Title: CT of pathogenic Vertebrae - R-55945 Migrated MorphoSource 1 Media Group Title: Vertebrae of R-55945 - pathogenic (multi-loop scan) Migrated MorphoSource 1 Media File Description: Multi-loop scan. Contains related artifacts.
Creator
--
Date created
--
Date uploaded
November 01, 2018

FILE OBJECT DETAILS Field Definitions

File name
R-55945_cancerloop_09January2018_cb_crop_rotate.zip
File format(s)
ZIP archive, TIFF
File size
894 MB
Image width
778
Image height
528
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.011000
Y pixel spacing
0.011000
Z pixel spacing
0.011000
Pixel spacing units
Millimeters
Slice thickness
--
Number of images in set
1,697

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Shimadzu SMX-100CT, Shimadzu Center for Environmental Forensics and Material Science (University of Texas at Arlington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Amphibian and Reptile Diversity Research Center, University of Texas at Arlington
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Alexander S. Hall provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uta:uta-r:55945 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Shimadzu Center for Environmental Forensics and Material Science (University of Texas at Arlington)
Creator
Justin L. Jacobs
Event date
--
Software
--
Description
35kv_40ua_polyacetal
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
6
Projections
1200
Voltage
35
Power
--
Amperage
40
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000063189: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Justin L. Jacobs
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000063189: Element Unspecified [CTImageSeries] [Etc] (this media)