Media 000064918: Scapula [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000064918
Media type
Mesh
Object element or part
Scapula
Side
Left
Orientation
--
Short description
Smooth Surface Mesh
Full description
Migrated MorphoSource 1 Media File Title: Smooth Surface Mesh Migrated MorphoSource 1 Media Group Title: microCT Volume File and Derivative Mesh Files Migrated MorphoSource 1 Media File Description: Correct chirality Migrated MorphoSource 1 Media Group Description: Correct chirality
Creator
--
Date created
--
Date uploaded
November 30, 2018

FILE OBJECT DETAILS

File format(s)
application/ply
File size
35.8 MB
Points
497,611
Polygons
999,454
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
34.987, 20.110, 65.829
Centroid coordinates
19.582, 14.585, 32.751
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
Doug Boyer
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1552848 (to DM Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by NSF BCS 1552848 (to DM Boyer). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:469 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Mackenzie Shepard
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
130
Power
0.01365
Amperage
105
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000064917: Scapula [CTImageSeries] [Etc] .

Processing Details

Creator
Mackenzie Shepard
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000064917: Scapula [CTImageSeries] [Etc] was processed to create derived Media 000064918: Scapula [Mesh] [Etc] (this media).

Processing Details

Creator
Mackenzie Shepard
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000064918: Scapula [Mesh] [Etc] (this media)