Media 000065909: Stapes [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000065909
Media type
Mesh
Object element or part
stapes
Side
Right
Orientation
--
Short description
mesh file
Full description
Migrated MorphoSource 1 Media File Title: mesh file Migrated MorphoSource 1 Media Group Title: micro CT volume and derivative meshes Migrated MorphoSource 1 Media File Description: correct chirality
Creator
--
Date created
--
Date uploaded
December 27, 2018

FILE OBJECT DETAILS

File format(s)
application/ply
File size
630 KB
Points
10,000
Polygons
19,992
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
1.167, 0.719, 1.095
Centroid coordinates
5.326, 2.829, 0.999
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Smithsonian, National Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in , the collection of which was funded by NSF. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:paleobiology:482353 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
nr
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
nr
Projections
nr
Voltage
nr
Power
--
Amperage
nr
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000065906: Petrosal Bone And Stapes [CTImageSeries] [Etc] .

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000065906: Petrosal Bone And Stapes [CTImageSeries] [Etc] was processed to create derived Media 000065909: Stapes [Mesh] [Etc] (this media).

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000065909: Stapes [Mesh] [Etc] (this media)