Media 000078669: Element Unspecified [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000078669
Media type
Mesh
File format(s)
application/stl
File size
103 MB
Object element or part
--
Side
--
Orientation
--
Short description
Mesh File (STL)
Full description
Migrated MorphoSource 1 Media File Title: Mesh File (STL) Migrated MorphoSource 1 Media Group Title: MicroCT and derivatives of uf:herp:79470, Calotes versicolor farooqi
Creator
--
Date created
--
Date uploaded
May 24, 2019
Points
1,074,729
Polygons
2,162,979
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
64.641, 31.012, 108.677
Centroid coordinates
-2.605, 1.048, -11.416
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
Florida Museum of Natural History, University of Florida
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:79470 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1250
Voltage
120
Power
0.03
Amperage
250
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000078669: Element Unspecified [Mesh] [Etc] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000078669: Element Unspecified [Mesh] [Etc] (this media)