GENERAL DETAILS Field Definitions
Media ID
000084882
Media type
Volumetric Image Series
Object element or part
Inner Ears
Object represented
Object taxonomy
Papio sp.
Object organization
Side
Midline
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Medical CT DICOM stack Migrated MorphoSource 1 Media Group Description: Scan of inner ear higher Z resolution (0.1 mm)
Creator
--
Date created
--
Date uploaded
August 14, 2019
FILE OBJECT DETAILS Field Definitions
File name
W744.zip
File format(s)
ZIP archive, DICOM
File size
66.2 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.292969
Y pixel spacing
0.292969
Z pixel spacing
0.100000
Pixel spacing units
Mm
Slice thickness
0.4
Number of images in set
241
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Biograph 40 TruePoint Tomograph, Center for Clinical Research (CCIR) (Washington University School of Medicine)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
snrpc:16368.W744
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Biograph 40 TruePoint Tomograph
Device facility
Center for Clinical Research (CCIR) (Washington University School of Medicine)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000084882: Inner Ears [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000084882: Inner Ears [CTImageSeries] [Etc] (this media)