Media 000098610: Head [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000098610
Media type
CTImageSeries
File format(s)
image/tiff
File size
803,335,455 bytes
Object element or part
head
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1281\\r\\n\\r\\nMaisano:\\r\\nTrogo: Scans of a head of Trogonophis wiegmanni elegans (Morocco, FMNH 109462) for Jessie Maisano of the Unversity of Texas and ATOL. Specimen scanned by Matthew Colbert 27 July 2005. \\r\\n\\r\\n16bit: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, no offset, empty container wedge, slice thickness 2 lines (= 0.02655 mm), S.O.D. 38.6 mm, 1800 views, 2 samples per view, inter-slice spacing 2 lines (= 0.02655 mm), field of reconstruction 10 mm (maximum field of view 12.649 mm), reconstruction offset 7900, scanner scale 4950, reconstruction scale 1300. Acquired with 15 slices per rotation. Drift- and ring removal processing done by Alison Mote based on correction of raw sinogram data using IDL routine “RK_SinoDeDrift” with parameter “driftlenth=21” and “RK_SinoRingProcSimul,” with default parameters. Total slices = 585.\\r\\n
Creator
--
Date created
--
Date uploaded
January 12, 2020
Image width
909
Image height
947
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.00977
Y pixel spacing
0.00977
Z pixel spacing
0.02655
Pixel spacing units
Mm
Number of images in set
585

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
The Field Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334961, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these dataoriginally appearing in Gauthier et al., 2012, with data collection funded by NSF EF-0334961 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:amphibians and reptiles:109462 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
2
Projections
1800
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000098610: Head [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Matthew Colbert
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000098610: Head [CTImageSeries] [Etc] (this media)