Media 000113684: Thoracic Vertebrae
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000113684
Media type
Volumetric Image Series
Object element or part
thoracic vertebrae
Object represented
Object taxonomy
Scutisorex somereni
Side
Midline
Orientation
--
Short description
Otsu segmented thoracic vertebral ROIs
Full description
Migrated MorphoSource 1 Media File Title: Otsu segmented thoracic vertebral ROIs Migrated MorphoSource 1 Media Group Title: Vertebral ROIs for all thoracic vertebrae of FMNH 189277
Creator
--
Date created
--
Date uploaded
March 25, 2020

FILE OBJECT DETAILS Field Definitions

File name
FMNH_189277_Scutisorex_somereni_ant_otsu.zip
File format(s)
ZIP archive, TIFF
File size
524 KB
Image width
29
Image height
29
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
21.973000
Y pixel spacing
21.973000
Z pixel spacing
21.973000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
905

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1811627
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: SM Smith and KD Angielczyk provided access to these data with data collection funded by NSF DBI-1811627. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Mammals:189277 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
SM Smith
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
850
Voltage
60
Power
--
Amperage
280
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000113684: Thoracic Vertebrae [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
SM Smith
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000113684: Thoracic Vertebrae [CTImageSeries] [Etc] (this media)