Media 000113846: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000113846: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000113846
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Puma concolor
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0293\\r\\n\\r\\nTheodor: \\r\\nConcoloF: Scans of entire skull and close-up of turbinates of Felis concolor, (female, LACM 85440), for Jessica Theodor and Blaire Van Valkenburgh of the Department of Organismic Biology, Ecology and Evolution, UCLA, in collaboration with Timothy Rowe of the University of Texas Department of Geological Sciences. Specimen had broken fangs and other teeth, probably damaged in transit due to insufficient packaging. Ketcham glued largest pieces back together.\\r\\n\\r\\nskull: Scans of entire skull. Scanned by Richard Ketcham on 25 October 2000. 512x512 16-bit TIFF images. P250D, 420 kV, 1.8 mA, 1 brass plate filter, empty mount wedge, no offset, integration time 32 ms, slice thickness 0.5 mm, S.O.D. 735 mm, 1000 views, 1 ray averaged per view, 1 sample per view, inter-slice spacing 0.5 mm, field of reconstruction 142 mm, reconstruction offset 550, reconstruction scale 950. \\n\\nRelated URL: http://digimorph.org/specimens/Puma_concolor/female/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Puma_concolor/female/
Creator
--
Date created
--
Date uploaded
March 28, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
67.9 MB
Image width
504
Image height
384
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.280000
Y pixel spacing
0.280000
Z pixel spacing
0.500000
Pixel spacing units
Millimeters
Slice thickness
--
Number of images in set
390
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Natural History Museum of Los Angeles County
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh and Tim Rowe provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
LACM:Mammals:85440
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1000
Voltage
420
Power
--
Amperage
1800
Surrounding material
empty mount
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000113846: Skull [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None