Media 000115561: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000115561: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000115561
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Chirixalus idiootocus
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1799\\r\\n\\r\\nHanken:\\r\\nchiri: Scans of the whole body of Chirixalus (Kurixalus) idiooticus (FMNH 231756) for Jim Hanken of Harvard University. Specimen scanned by Matthew Colbert 21 December 2007. \\r\\n\\r\\n16bit: 1024x1024 16-bit TIFF images. II, 200 kV, 0.115 mA, intensity control on, high power mode, no filter, air wedge, no offset, slice thickness 1 line (= 0.02746 mm), S.O.D. 79 mm, 1400 views, 3 samples per view, inter-slice spacing 1 line (= 0.02746 mm), field of reconstruction 19 mm (maximum field of view 26.16865 mm), reconstruction offset 5000, reconstruction scale 6700. Acquired with 31 slices per rotation and 25 slices per set. Ring-removal processing done by Rachel Racicot based on correction of raw sinogram data using IDL routine “RK_SinoRingProcSimul” with default parameters. Reconstructed off-center with X offset = -0.25 and Y offset = 0.25. Deleted last six duplicate slices of each rotation. Deleted first 11 and last 28 slices of entire dataset. Total final slices = 1286.\\r\\n\\n\\nRelated URL: http://www.digimorph.org/specimens/Chirixalus_idiootocus/whole/ Migrated MorphoSource 1 Media Group Description: Related URL: http://www.digimorph.org/specimens/Chirixalus_idiootocus/whole/
Creator
--
Date created
--
Date uploaded
May 04, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
1.5 GB
Image width
970
Image height
768
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.018550
Y pixel spacing
0.018550
Z pixel spacing
0.027460
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,286
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
The Field Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DEB-0345885, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: James Hanken provided access to these data , with data collection funded by NSF DEB-0345885 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:Amphibians and Reptiles:231756
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1400
Voltage
200
Power
--
Amperage
115
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000115561: Whole Body [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000115561: Whole Body [CTImageSeries] [Etc] (this media)