Media 000154897: Element Unspecified
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000154897: Element Unspecified
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000154897
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Heterocephalus glaber
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Micro-CT volume and derivative mesh files
Creator
--
Date created
--
Date uploaded
August 10, 2020
FILE OBJECT DETAILS Field Definitions
File name
Heterocephalus_glaber_NHMUK_91.235_8bit_cropped_increment2.zip
File format(s)
ZIP archive, TIFF
File size
1.99 GB
Image width
2202
Image height
1182
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.026028
Y pixel spacing
0.026028
Z pixel spacing
0.052055
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,919
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Natural History Museum, London
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Roger Benson provided access to these dataoriginally appearing in … , the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nhmuk:91.235
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
Roger Benson, Tom Davies
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1200
Voltage
105
Power
--
Amperage
115
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000154897: Element Unspecified [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Roger Benson, Tom Davies
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000154897: Element Unspecified [CTImageSeries] [Etc] (this media)