Media 000158535: 4th Cervical Vertebra
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000158535
Media type
Mesh
Object element or part
4th cervical vertebra
Object represented
Object taxonomy
Ephippiorhynchus asiaticus
Object organization
Side
Midline
Orientation
--
Short description
Ephippiorhynchus asiaticus C4 mesh
Full description
Migrated MorphoSource 1 Media File Title: Ephippiorhynchus asiaticus C4 mesh Migrated MorphoSource 1 Media Group Title: HRXCT scan
Creator
--
Date created
--
Date uploaded
August 19, 2020

FILE OBJECT DETAILS Field Definitions

File name
E_asiaticus_19694_C4.ply
File format(s)
PLY
File size
16 MB
Points
121411
Polygons
242914
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
20.021, 34.465, 19.287
Centroid coordinates
11.503, 18.733, 8.789
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DGE-1246908, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Andrew Moore provided access to these data , with data collection funded by NSF DGE-1246908 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:BIRDS:USNM 19694 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
3000
Voltage
180
Power
--
Amperage
220
Surrounding material
0.25 pF gain
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000116257: Pre Synsacral Vertebrae [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000116257: Pre Synsacral Vertebrae [CTImageSeries] [Etc] was processed to create derived Media 000158535: 4th Cervical Vertebra [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000158535: 4th Cervical Vertebra [Mesh] [Etc] (this media)