Media 000166152: Posterior Part Of Cranium
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000166152
Media type
Volumetric Image Series
Object element or part
Posterior part of cranium
Object represented
Object taxonomy
Ekweeconfractus amorui
Object organization
Side
NotApplicable
Orientation
--
Short description
MicroCT Image stack
Full description
Migrated MorphoSource 1 Media File Title: MicroCT Image stack Migrated MorphoSource 1 Media Group Title: microCT scan of the neurocranium and derivative files Migrated MorphoSource 1 Media Group Description: Scan of the posterior half of the crushed cranium
Creator
--
Date created
--
Date uploaded
October 30, 2020

FILE OBJECT DETAILS Field Definitions

File name
KNM_MO64199_80kV_130uA_1fps_2fa_3.1Al_pt2.zip
File format(s)
ZIP archive, TIFF
File size
550 MB
Image width
1080
Image height
2000
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.066700
Y pixel spacing
0.066700
Z pixel spacing
0.066700
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,686

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225/320 LC, Microfocus X-ray Computed Tomography (CT) facility of the Palaeosciences Centre (University of the Witwatersrand)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
National Museums of Kenya
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1241817
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: National Museums of Kenya provided access to these dataoriginally appearing in Flink et al. 2021 the collection of which was funded by NSF BCS 1241817. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object knm:mo:64199 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225/320 LC
Device facility
Microfocus X-ray Computed Tomography (CT) facility of the Palaeosciences Centre (University of the Witwatersrand)
Creator
Kudakwashe Jakata
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
80
Power
--
Amperage
130
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000166152: Posterior Part Of Cranium [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Kudakwashe Jakata
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000166152: Posterior Part Of Cranium [CTImageSeries] [CT] (this media)