Media 000167057: Element Unspecified
Open Download
Type
Video
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000167057: Element Unspecified
Open Download
Type
Video
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000167057
Media type
Video
Object element or part
--
Object represented
Object taxonomy
Wallichia disticha
Object organization
Side
--
Orientation
--
Short description
Wallichia disticha CT slice video, transverse plane
Full description
Migrated MorphoSource 1 Media File Title: Wallichia disticha CT slice video, transverse plane Migrated MorphoSource 1 Media Group Title: Wallichia disticha fruit CT scan
Creator
--
Date created
--
Date uploaded
November 18, 2020
FILE OBJECT DETAILS Field Definitions
File name
Wallichia_disticha_BH000154540_XS.mpeg
File format(s)
MPEG
File size
210 MB
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DEB-1701645
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
bh:000154540
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
Creator
Kelly Matsunaga
Event date
--
Software
--
Description
Reconstructed Volume Dimensions: VoxelsX=1576 VoxelsY=1690 VoxelsZ=1946; Panel position: -140
Description attachment
None
Reference attachment
None
Exposure time
2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
2
Projections
3141
Voltage
40
Power
--
Amperage
135
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000167054: Element Unspecified [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Kelly Matsunaga
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000167054: Element Unspecified [CTImageSeries] [CT]
was processed
to create
derived
Media 000167057: Element Unspecified [Video] [CT] (this media).
Processing Details Field Definitions
Creator
Kelly Matsunaga
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000167057: Element Unspecified [Video] [CT] (this media)