Media 000170717: Wrist [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000170717
Media type
CTImageSeries
Object element or part
wrist
Side
--
Orientation
--
Short description
HRXCT scan - wrist
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0827 Simmons: Furipterus: Scans of the wrist of Furipterus horrens (AMNH 244493; no locality info) for Dr. Nancy Simmons of the American Museum of Natural History and Dr. Timothy Rowe of the Department of Geological Sciences, The University of Texas at Austin. Scanned by Matthew Colbert 10 March 2003. wrist/16bitrf: 512x512 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, empty wedge, no offset, slice thickness 1 line (= 0.0134 mm), S.O.D. 39 mm, 1000 views, 5 samples per view, inter-slice spacing 1 line (= 0.0134 mm), field of reconstruction 6.4 mm (maximum field of view 12.78 mm), reconstruction offset 10000, reconstruction scale 1500. Reconstructed off-center: x = 1, y = 1. Acquired with 27 slices per rotation. Flash-removal (to reduce spikes caused by sudden changes in X-ray intensity) and ring-removal processing done by Rachel Racicot based on correction of raw sinogram data using IDL routines “RK_SinoDeSpike”, then “RK_SinoRingProcSimul”, both with default parameters. Deleted original slices 26-27. Total slices = 187.
Creator
--
Date created
March 10, 2003
Date uploaded
January 07, 2021

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
37 MB
Image width
368
Image height
302
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.012500
Y pixel spacing
0.012500
Z pixel spacing
0.013400
Pixel spacing units
Mm
Number of images in set
187

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
IP holder
AMNH Dept of Mammalogy
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DEB-9873663, DBI-1902242
Publisher
oUTCT PEN
Cite as
Nancy Simmons provided access to these data, with data collection funded by NSF DEB-9873663 and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:mammals:m-244493 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
March 10, 2003
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
5
Projections
1000
Voltage
120
Power
--
Amperage
200
Surrounding material
empty
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000170717: Wrist [CTImageSeries] [CT] (this media).

Processing Details

Creator
Matthew Colbert
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000170717: Wrist [CTImageSeries] [CT] (this media)