Media 000344918: Talus [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
4 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000344918
Media type
Mesh
File format(s)
application/ply
File size
3.11 MB
Object element or part
Talus
Side
Right
Orientation
--
Short description
Smooth surface file
Full description
--
Creator
--
Date created
--
Date uploaded
February 16, 2021
Points
47,074
Polygons
94,144
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.209, 6.678, 3.695
Centroid coordinates
8.849, 6.173, 6.191
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
dlc:1992m
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich, Darbi Griffith
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
155
Power
0.018600000000000002
Amperage
120
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000016396: Full Body [CTImageSeries] [Etc]
.
Processing Details
Creator
Gabriel Yapuncich, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000016396: Full Body [CTImageSeries] [Etc]
was processed
with 1 activity
to create
derived
Media 000344918: Talus [Mesh] [CT]
(this media).
Processing Details
Creator
Gabriel Yapuncich
Date processed
2021-02-15
Software
Avizo 2019.3
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
Avizo 2019.3
Description
Media produced by this event on MorphoSource
Media 000344918: Talus [Mesh] [CT] (this media)