Media 000346412: Hind Limbs [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000346412
Media type
CTImageSeries
File format(s)
image/tiff
File size
1,845,054,544 bytes
Object element or part
hind limbs
Side
NotApplicable
Orientation
--
Short description
DICECT Zstack of hindlimbs and vent
Full description
--
Creator
--
Date created
--
Date uploaded
February 25, 2021
Image width
1887
Image height
994
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.0228028
Y pixel spacing
0.0228028
Z pixel spacing
0.0228028
Pixel spacing units
Mm
Number of images in set
2,022

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
IP holder(s) (Name, Type)
--
Funding attribution
--
Publisher
--
Cite as
--
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:186878 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
2021-02-23
Software
Phonix Datos X
Description
DICECT of UF-H-186878 pes
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
Yes
Filter
--
Frame averaging
3
Projections
1800
Voltage
125
Power
31.25
Amperage
250
Surrounding material
air
Xray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston
Rotation number
1800
Phase contrast
No
Optical magnification
Yes
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000346412: Hind Limbs [CTImageSeries] [CT] (this media).

Processing Details

Creator
Edward Stanley
Date processed
2021-02-25
Software
DatosX R
Description
Reconstruction
Description attachment
None

Processing Activity 1: Reconstruction

Software
DatosX R
Description
reconstruction

Processing Activity 2: Background Removal and/or Masking

Software
VGStudioMax 3.4
Description
Background removal

Media produced by this event on MorphoSource


Media 000346412: Hind Limbs [CTImageSeries] [CT] (this media)