Media 000346412: Hind Limbs
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000346412
Media type
Volumetric Image Series
Object element or part
hind limbs
Object represented
Object taxonomy
Aristelliger lar
Side
NotApplicable
Orientation
--
Short description
DICECT Zstack of hindlimbs and vent
Full description
--
Creator
--
Date created
--
Date uploaded
February 25, 2021

FILE OBJECT DETAILS Field Definitions

File name
UF-H-186878-pes.zip
File format(s)
ZIP archive, TIFF
File size
1.72 GB
Image width
1887
Image height
994
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.022803
Y pixel spacing
0.022803
Z pixel spacing
0.022803
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,022

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:186878 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
February 23, 2021
Software
Phonix Datos X
Description
DICECT of UF-H-186878 pes
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
3
Projections
1800
Voltage
125
Power
31.250
Amperage
250
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
2014
Detector pixels size X
--
Detector pixels Y
2024
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston
Rotation number
1800
Phase contrast
No
Optical magnification
Yes
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000346412: Hind Limbs [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
February 25, 2021
Software
DatosX R
Description
Reconstruction
Description attachment
None

Processing Activity 1: Reconstruction

Software
DatosX R
Description
reconstruction

Processing Activity 2: Background Removal and/or Masking

Software
VGStudioMax 3.4
Description
Background removal

Media produced by this event on MorphoSource

Media 000346412: Hind Limbs [CTImageSeries] [CT] (this media)