Media 000358663: Skull [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
Interactive/Embeddable Media Preview is currently unavailable. Please check back later.
4 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000358663
Media type
Mesh
File format(s)
application/ply
File size
667 MB
Object element or part
Skull
Side
NotApplicable
Orientation
--
Short description
Skull with colored elements
Full description
Skull with elements colored as seen in Blackburn Lab Sketchfab model: https://skfb.ly/onCyK
Creator
--
Date created
--
Date uploaded
April 19, 2021
Points
8,590,717
Polygons
2,863,661
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
36.660, 49.911, 33.089
Centroid coordinates
1.183, 4.975, 0.090
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
uf:herp:11978
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2000
Voltage
150
Power
--
Amperage
180
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000011009: Tuatara Skull [CTImageSeries] [Etc]
.
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000011009: Tuatara Skull [CTImageSeries] [Etc]
was processed
with 1 activity
to create
derived
Media 000358663: Skull [Mesh] [CT]
(this media).
Processing Details
Creator
Jaimi Gray
Date processed
2021-04-19
Software
VG Studio Max and Blender
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
VG Studio Max and Blender
Description
Skull elements isolated and meshes generated in VG Studio Max. Meshes cleaned/edited in Blender.
Media produced by this event on MorphoSource
Media 000358663: Skull [Mesh] [CT] (this media)