Media 000360675: Rostral Half Of Body [CTImageSeries] [CT]
Represents:
Biological Specimen
Not in Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000360675
Media type
CTImageSeries
Object element or part
Rostral half of body
Side
--
Orientation
--
Short description
Rostral portion of body
Full description
This scan includes the rostral portion of the body, from the rostral tip of the head to the 6th lumbar vertebra. Due to the field of view limits of the scan volume, the right forelimb is cut off at the middle of the humeral shaft.
Creator
--
Date created
--
Date uploaded
April 27, 2021
FILE OBJECT DETAILS
File format(s)
application/dicom
File size
233 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.444432
Y pixel spacing
0.444432
Pixel spacing units
Mm
Slice thickness
0.444432
Number of images in set
1,078
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Animage Fidex CT, Keck XROMM Core Facility (Brown University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
We thank the Keck XROMM Core Facility (Brown University) for their donation of scanning time.
Publisher
3D Anatomy Studios
Cite as
3D Anatomy Studios (2021). CT scan of a domestic cat (Felis catus) purchased from Carolina Biological Supply, ID 3DAS-ID00001 (published dicom files). Retrieved from Morphosource ARK: http://n2t.net/ark:/87602/m4/360675.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
3DAS:00001
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Animage Fidex CT
Device facility
Keck XROMM Core Facility (Brown University)
Creator
3D Anatomy Studios
Date
February 26, 2021
Software
Animage Fidex
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
745
Voltage
110
Power
--
Amperage
0.1
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000360675: Rostral Half Of Body [CTImageSeries] [CT]
(this media).
Processing Details
Creator
3D Anatomy Studios
Date processed
February 26, 2021
Software
Animage Fidex
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
Animage Fidex
Description
Media produced by this event on MorphoSource
Media 000360675: Rostral Half Of Body [CTImageSeries] [CT] (this media)