Media 000363691: Nasal
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS

Media ID
000363691
Media type
Mesh
Object element or part
nasal
Object represented
Object taxonomy
Majungasaurus crenatissimus
Side
Midline
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 14, 2021

FILE OBJECT DETAILS

File format(s)
application/ply
File size
271 MB
Points
3454342
Polygons
6989176
Map type
Normal
UV coordinates
False
Vertex color
False
Bounding box dimensions
104.853, 87.406, 330.292
Centroid coordinates
2.414, -4.593, -3.893
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR_1123642; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1525915
Publisher
Ohio University; Joseph R. Groenke; Mahajanga Basin Project; Patrick M. O'Connor
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:pr:2100 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Date
March 06, 2012
Software
GE
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
250
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
541
Source detector distance
949.1
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Spiral

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000363688: Nasal [CTImageSeries] [CT].

Processing Details

Creator
Groenke, Joseph
Date processed
February 26, 2021
Software
Avizo
Description
crops for batch scans and export as dicoms
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000363688: Nasal [CTImageSeries] [CT] was processed to create derived Media 000363691: Nasal [Mesh] [CT] (this media).

Processing Details

Creator
Groenke, Joseph
Date processed
February 26, 2021
Software
Avizo
Description
export as ply format from isosurface rendering
Description attachment
None

Media produced by this event on MorphoSource

Media 000363691: Nasal [Mesh] [CT] (this media)