Media 000365455: Head Mri T2 512 [CTImageSeries] [MRI]
Represents:
Biological Specimen
Not in Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000365455
Media type
CTImageSeries
File format(s)
image/tiff
File size
54.3 MB
Object element or part
head MRI T2 512
Side
--
Orientation
--
Short description
Data is the head of a 72 year old male donor. The donor was preserved in formalin and the blood vessels were filled with araldite-F. Before freezing, MRI and CAT imaging was preformed.
Full description
--
Creator
--
Date created
--
Date uploaded
May 31, 2021
Image width
512
Image height
512
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.477000
Y pixel spacing
0.477000
Z pixel spacing
1.000000
Pixel spacing units
Mm
Slice thickness
1
Number of images in set
229
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
Magnetic Resonance Imaging (MRI)
Device
Philips Gyroscan NT, University Medical Center Utrecht (University Medical Center Utrecht)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nlm:NLM:2
was imaged to create
undeposited raw media.
Imaging Details
Modality
Magnetic Resonance Imaging (MRI)
Device
Philips Gyroscan NT
Device facility
University Medical Center Utrecht (University Medical Center Utrecht)
Creator
--
Date
2021-06-01
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000365455: Head Mri T2 512 [CTImageSeries] [MRI]
(this media).
Processing Details
Creator
Date processed
2021-05-31
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource

Media 000365455: Head Mri T2 512 [CTImageSeries] [MRI] (this media)