Media 000366002: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000366002
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Hylobates hoolock
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - sacrum
Full description
University of Texas High-Resolution X-ray CT Facility Archive 2647 Russo: hoohooA: Scans of two sacra of Hylobates hoolock (AMNH 83426, male, India, Assam, Canchang Pani, at top of field of view; AMNH 83415, male, same locality, at bottom of field of view) for Gabrielle Russo of UT Anthropology. Specimens scanned by Matthew Colbert 20 December 2011. 16bitrot: 1024x1024 16-bit TIFF images. II, 200 kV, 0.22 mA, intensity control off, high-power mode, no filter, empty container wedge, no offset, slice thickness 1 line ( = 0.06341 mm), S.O.D. 182 mm, 1800 views, 2 samples per view, inter-slice spacing 1 line ( = 0.06341 mm), field of reconstruction 60.5 mm (maximum field of view 60.5 mm), reconstruction offset 4000, reconstruction scale 6000. Acquired with 31 slices per rotation and 25 slices per set. Ring-removal processing done by Julia Holland based on correction of raw sinogram using IDL routine “RK_SinoRingProcSimul” with parameter “bestof5=11.” Deleted first 3 and last 3 duplicate slices from each rotation. Rotation correction processing done by Julia Holland using IDL routine “DoRotationCorrection.” Deleted first 10 and last 2 blank slices. Total final slices = 1090.
Creator
12/20/2011
Date created
December 20, 2011
Date uploaded
June 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
1.78 GB
Image width
1024
Image height
585
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.059080
Y pixel spacing
0.059080
Z pixel spacing
0.063410
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,090

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
AMNH Dept of Mammalogy
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Funding for scanning was provided by Gabrielle Russo. Data upload to MorphoSource was funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:mammals:83426 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000366002: Element Unspecified [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
June 02, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000366002: Element Unspecified [CTImageSeries] [CT] (this media)