Media 000367203: Skull [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000367203
Media type
Mesh
Object element or part
skull
Side
Midline
Orientation
--
Short description
cranium and right hemi-mandible in matrix
Full description
--
Creator
--
Date created
--
Date uploaded
June 09, 2021
FILE OBJECT DETAILS
File format(s)
application/ply
File size
32.3 MB
Points
857,008
Polygons
1,615,958
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
1503.109, 925.651, 903.212
Centroid coordinates
-204.545, 53.727, -36.794
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
2
Number of processing events
2
(5 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scientific Measurement Systems, Inc. Minatron 205, Rocketdyne (Boeing North America, Inc.)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
fmnh:pr:2081
was imaged to create
raw media
Media 000369673: Skull [CTImageSeries] [CT]
.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scientific Measurement Systems, Inc. Minatron 205
Device facility
Rocketdyne (Boeing North America, Inc.)
Creator
Jeff Anders; Tom Koehnlein
Date
January 01, 1998
Software
--
Description
cranium and right hemi-mandible in matrix scanned for Chris Brochu
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
Media produced by this event on MorphoSource
STEP 2: IMAGE PROCESSING
Raw
Media 000369673: Skull [CTImageSeries] [CT]
was processed
with 2 activities
to create
derived
Media 000366912: Skull [CTImageSeries] [CT]
.
Processing Details
Creator
Larry Witmer, Ryan Ridgely
Date processed
January 01, 2009
Software
Amira
Description
This scan is archived with x-y plane pixel dimensions determined by Witmer and Ridgely (2009, p.1268; https://doi.org/10.1002/ar.20983) based on their experience with the data they had available to them, which consisted of the processed JPG slices on the CD-ROM included with Brochu (2003; https://doi.org/10.1080/02724634.2003.10010947).
Due to apparent distortion, Witmer and Ridgley corrected the pixel dimensions to 0.0496111mm, which differ only slightly from those reported in the original scan materials from Rocketdyne (0.49688mm).
Description attachment
None
Processing Activity 1: Bit Depth Change
Software
Description
original data was 16bit. the current dataset is 8bit
Processing Activity 2: Transform: Scale
Software
Description
x-y plane values used for this scan differ from those of parent file by 0.15%
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000366912: Skull [CTImageSeries] [CT]
was processed
with 3 activities
to create
derived
Media 000367203: Skull [Mesh] [CT]
(this media).
Processing Details
Creator
Edward Stanley, Doug Boyer
Date processed
June 08, 2021
Software
Geomagic
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
VG Studiomax
Description
Processing Activity 2: Mesh and/or Point Cloud Texturing
Software
VG Studiomax
Description
Processing Activity 3: Smoothing/Noise Reduction
Software
Geomagic
Description
Media produced by this event on MorphoSource
Media 000367203: Skull [Mesh] [CT] (this media)