Media 000380553: Calcaneus
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000380553
Media type
Mesh
Object element or part
calcaneus
Object represented
Object taxonomy
Ignacius clarkforkensis
Object organization
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
doug boyer
Date created
August 27, 2021
Date uploaded
August 28, 2021

FILE OBJECT DETAILS Field Definitions

File name
UMMP82606_calc.ply
File format(s)
PLY
File size
48.8 MB
Points
673080
Polygons
1346164
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.581, 7.203, 3.916
Centroid coordinates
4.285, 4.503, 1.782
Units of point coordinates
Millimeters

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Regents of the University of Michigan
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS-1552848
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ummp:vp:82606 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
doug boyer; Stephen Chester
Event date
December 16, 2013
Software
CT Scan Pro
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
1
Projections
1200
Voltage
130
Power
--
Amperage
114
Surrounding material
polyurethane foam
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
63.940052986145
Source detector distance
952.0111
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000380535: Calcaneus [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
doug boyer
Event date
April 23, 2014
Software
CT scan pro
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Ct scan pro
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000380535: Calcaneus [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000380553: Calcaneus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
doug boyer
Event date
August 27, 2021
Software
Avizo
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description

Media produced by this event on MorphoSource

Media 000380553: Calcaneus [Mesh] [CT] (this media)