Media 000382037: Whole Body
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

GENERAL DETAILS Field Definitions

Media ID
000382037
Media type
Volumetric Image Series
Object element or part
whole body
Object taxonomy
Eumicrotremus orbis
Side
--
Orientation
--
Short description
oVert# 03412
Full description
--
Creator
Jonathan Huie
Date created
--
Date uploaded
September 07, 2021

FILE OBJECT DETAILS Field Definitions

File name
Eorbis_UWFC_028374_overt_03412.zip
File format(s)
ZIP archive, BMP
File size
881 MB
Image width
1342
Image height
1457
Color space
--
Color depth
8
Compression
BI_RGB; 0; None
Series type
Reconstructed image stack
X pixel spacing
0.029839
Y pixel spacing
0.029839
Z pixel spacing
0.029839
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,397

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1701714; NSF DBI-1701665
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UWFC:ADULT COLLECTION:UW 028374 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Jonathan Huie; Karly Cohen
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.15
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000382037: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Jonathan Huie
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000382037: Whole Body [CTImageSeries] [CT] (this media)