Media 000382292: Desmatosuchus Smalli Ucmp 27410 Braincase [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000382292
Media type
CTImageSeries
File format(s)
image/tiff
File size
36.5 MB
Object element or part
Desmatosuchus smalli UCMP 27410 Braincase
Side
--
Orientation
--
Short description
Desmatosuchus smalli UCMP 27410 Braincase
Full description
Desmatosuchus smalli UCMP 27410 Braincase
Creator
--
Date created
June 24, 2006
Date uploaded
September 08, 2021
Image width
315
Image height
281
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.390625
Y pixel spacing
0.390625
Z pixel spacing
0.625000
Slice thickness
.625
Number of images in set
286
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed Ultra 64 Multislice CT scanner, OhioHealth O'Bleness Hospital (OhioHealth O'Bleness Hospital)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
University of California Regents; University of California Museum of Paleontology
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UCMP:V:27410
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed Ultra 64 Multislice CT scanner
Device facility
OhioHealth O'Bleness Hospital (OhioHealth O'Bleness Hospital)
Creator
--
Date
2006-06-24
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
120
Power
--
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000382292: Desmatosuchus Smalli Ucmp 27410 Braincase [CTImageSeries] [CT]
(this media).
Processing Details
Creator
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource

Media 000382292: Desmatosuchus Smalli Ucmp 27410 Braincase [CTImageSeries] [CT] (this media)