Media 000388066: Whole Fish [CTImageSeries] [CT]
Represents:
Biological Specimen
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000388066
Media type
CTImageSeries
File format(s)
image/bmp
File size
70.5 MB
Object element or part
WHOLE FISH
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Adam Summers
Date created
January 16, 2020
Date uploaded
October 01, 2021
Image width
404
Image height
404
Color space
--
Color depth
8
Compression
None
X pixel spacing
0.006700
Y pixel spacing
0.006700
Z pixel spacing
0.006700
Slice thickness
0.0067
Number of images in set
1,872
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
0
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
wam:rept:P.34629-005
was imaged to create
this media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Adam Summers
Date
2020-01-16
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
6.7
Detector pixels Y
--
Detector pixel size Y
6.7
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
Media produced by this event on MorphoSource
Media 000388066: Whole Fish [CTImageSeries] [CT] (this media)