Media 000388622: Cranium [Mesh] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000388622
Media type
Mesh
File format(s)
application/ply
File size
52,122,300 bytes
Object element or part
Cranium
Side
--
Orientation
--
Short description
Cranium
Full description
Any 3D surface uploaded for this specimen/element was produced with either the Isosurface or LabelField functions in AVIZO 7 or later, and it was subsequently processed in Geomagic Studio/Wrap (e.g., cleaning, filling holes).
Creator
Alexander Prucha
Date created
October 04, 2021
Date uploaded
October 04, 2021
Points
1,371,541
Polygons
2,743,306
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
120.411, 179.844, 102.432
Centroid coordinates
61.325, 107.288, -53.791
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225, Center for Nanoscale Systems (Harvard University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
Museum of Comparative Zoology, Harvard University
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mcz:mamm:38020 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX ST 225
Device facility
Center for Nanoscale Systems (Harvard University)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
--
Projections
1500
Voltage
80
Power
0.01
Amperage
120
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000004397: Element Unspecified [CTImageSeries] [Etc] .

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000004397: Element Unspecified [CTImageSeries] [Etc] was processed to create derived Media 000388622: Cranium [Mesh] [CT] (this media).

Processing Details

Creator
Alexander Prucha
Date processed
--
Software
AVIZO 7
Description
Any 3D surface uploaded for this specimen/element was produced with either the Isosurface or LabelField functions in AVIZO 7 or later, and it was subsequently processed in Geomagic Studio/Wrap (e.g., cleaning, filling holes).
Description attachment
None

Media produced by this event on MorphoSource


Media 000388622: Cranium [Mesh] [CT] (this media)