Media 000408610: Pelvis
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000408610: Pelvis
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000408610
Media type
Mesh
Object element or part
Pelvis
Object represented
Object taxonomy
Agamodon anguliceps
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
S. Swank
Date created
January 06, 2021
Date uploaded
December 20, 2021
FILE OBJECT DETAILS Field Definitions
File name
Aa.263912.325.ply
File format(s)
PLY
File size
155 MB
Points
3021512
Polygons
3658232
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.681, 9.568, 20.723
Centroid coordinates
12.900, -9.894, 8.743
Units of point coordinates
No Value Entered, Millimeter Default
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Perkin Elmer Quantum GX2, LUC Department of Biology (Loyola University Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DEB-1456462
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:Amphibians and Reptiles:263912
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
LUC Department of Biology (Loyola University Chicago)
Creator
--
Event date
January 06, 2021
Software
InVesalius 3.1; MeshLab 2020.12
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
4 min
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
65-70 kV
Power
--
Amperage
100-114 mA
Surrounding material
Plastic bag
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000408610: Pelvis [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Sam Swank
Event date
January 06, 2021
Software
--
Description
--
Description attachment
None
Processing Activity 1: Photos to Mesh
Software
InVesalius
Description
created .ply file using a manual threshold